Test Code PVAS SEMEN ANALYSIS, POST VASECTOMY
Additional Codes
Software | Test Code |
---|---|
Label Text | PVAS |
EPIC | LAB218 |
Performing Laboratory
NorDx Laboratories
Useful For
Verifying that sperm have been successfully excluded from the ejaculate after vasectomy
Method Name
The primary method for PVAS testing is manual via Light Microscopy.
If a sperm count is reflexed, the primary method remains Light Microscopy by hemocytometer. In some instances, the sperm count may be assessed via automation utilizing the SQA-Vision (SQA) analyzer located at the NorDx Scarborough Campus. The MES SQA-Vision is a high-performance analytical medical device that combines optoelectronics, computer algorithms, and video microscopy for analysis.
Reference Values
The success of a vasectomy is assessed by the presence of <100,000 non-motile sperm/mL at six months after vasectomy.
Report information will include the presence or absence of sperm cells and, if present, their concentration and motility status.
Days and Times Test Performed
Monday through Thursday
Report Available
1 Day
Profile Information
Individual Test Description |
---|
COLLECTION TIME, SEMEN |
DAYS OF ABSTINENCE |
EXAMINATION TIME, SEMEN |
MOTILITY, POST VASECTOMY |
SPERM COUNT, POST VASECTOMY |
WBC, POST VASECTOMY |
Specimen Type
Semen – entire ejaculate
Preferred Container
Sterile Container
Preferred Volume
Semen: (Sterile Container) – Entire ejaculate
Specimen Collection and Handling
- Forward the total ejaculate at ambient temperature (68 – 90°F or 20 – 32°C).
- To ensure the most viable semen specimen, semen collections are to be done at the designated NorDx locations listed above only.
- Hours for collection of semen specimens are Monday through Thursday from 8:00 A.M. to 3:00 P.M.
- Private and clean spaces, as well as collection instructions are available to patients who present to produce a semen specimen.
- Collection instructions and container will be provided at the designated locations.
- Post Vasectomy Semen Collection Instructions Form must accompany the specimen.
Add On Capable
Not Permitted
Advance Beneficiary Notice Requirements
No ABN Required
CPT Code Information
CPT Code |
CPT Description |
CPT Disclaimer |
---|---|---|
89321 | Semen Analysis, Sperm Presence and Motility of Sperm, if Performed |
Keywords
POST VASECTOMY ANALYSIS
SEMEN ANALYSIS
Performing Laboratory Location
NorDx Laboratories
LOINC Code Information
29990-9
Rejection Information
- Any specimen that leaked out of the container
- Any specimen greater than 36 hours post collection.
Note: A disclaimer will be added to the report for specimens received 2 hours or more past collection if sperm are present and non-motile.
- Any specimen that is grossly contaminated by lubricants or other types of material