Test Code ACTHF CORTROSYN STIMULATION TEST (0, 1/2 HOUR, 1 HOUR)
Additional Codes
Software | Test Code |
---|---|
Label Text | ACTHF |
EPIC | LAB711 |
Performing Laboratory
NorDx Laboratories
Useful For
The evaluation of adrenal insufficiency in suspected adrenal biosynthetic defect or adrenocorticotropic hormone (ACTH) unresponsiveness.
Test includes three serum cortisol determinations--one at 0 minutes, one at 30 minutes, and one at 60 minutes.
Method Name
Electrochemiluminescent Immunoassay (ECLIA)
Reference Values
Cortisol level: > 18 ug/dL before or after the ACTH injection
Days and Times Test Performed
Monday through Friday
Report Available
1 Day
Profile Information
Individual Test Description |
---|
CORTISOL, BASELINE |
CORTISOL, 30 MINUTES |
CORTISOL, 60 MINUTES |
Specimen Type
Serum
Preferred Container
Serum Separator Tube (SST)
Preferred Volume
Serum: 1 mL (Serum Separator Tube (SST))
Minimum Volume
Serum: 0.5 mL (Serum Separator Tube (SST))
Specimen Collection and Handling
1. Draw baseline blood in a serum gel tube.
2. Immediately after drawing baseline, clinician administers 0.25 mg ACTH (Cortrosyn) injection.
3. Draw second blood specimen 30 minutes post injection.
4. Draw third blood specimen 60 minutes post injection.
5. Label tubes with collection time.
To Process:
1. Send 1.0 mL of serum from each specimen (pre and post injection).
2. Label tubes with the collection time.
Specimen Stability Information
Specimen Type: Serum
Frozen: 3 Months
Refrigerated: 4 Days
Must be spun/separated within: 2 Hours
Add On Capable
Not Permitted
Advance Beneficiary Notice Requirements
No ABN Required
CPT Code Information
CPT Code |
CPT Description |
CPT Disclaimer |
---|---|---|
80400 | ACTH Stimulation Panel for Adrenal Insufficiency (Must include Cortisol) | |
82533 | Cortisol, Total | If indicated |
Performing Laboratory Location
NorDx Laboratories
Clinical Significance
No sample should be collected on patients receiving therapy with high biotin doses (i.e. biotin therapy for Multiple Sclerosis or oncology patients; skin, hair and nail supplements, or multivitamins containing > 5 mg/day) until at least 12 hours after the last biotin administration. If unsure, or if the clinical picture does not fit the results please contact the laboratory . We have methods to check for biotin interference as well as for any other interferences and for the accuracy of the results.
Biotin interference would falsely increase the result of this assay.
Acceptable Alternative Container(s)
Plasma Separator Tube (PST)
Red Top Tube