Sign in →

Test Code NICKP / 071571-LC NICKEL, PLASMA

Additional Codes

Software Test Code
Label Text NICKP
EPIC                                                LAB10109                                  
LabCorp 071571

Performing Laboratory

Laboratory Corporation of America (LabCorp)

Useful For

Monitoring exposure to nickel

Method Name

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

Reference Values

Environmental exposure: 0.6 – 7.5 µg/L

Occupational exposure: 3.0 – 11.0 µg/L may be seen in refinery workers

Days and Times Test Performed

Monday through Friday

Report Available

1 Day

Specimen Type

Plasma

Preferred Container

Royal Blue Top Tube (EDTA)

Preferred Volume

Plasma: 2 mL (Royal Blue Top Tube (EDTA))

Minimum Volume

Plasma: 0.6 mL (Royal Blue Top Tube (EDTA))

Specimen Collection and Handling

1. Submit original unopened tube or plasma removed from a royal blue-top tube, and transfer to a metal-free plastic transport tube.

2. Maintain submit sample at room temperature.

Specimen Stability Information

Specimen Type: Plasma

Frozen: 14 Days

Refrigerated: 14 Days

Room Temp: 14 Days

Note: Stable x3 freeze/thaw cycles.

Add On Capable

Contact Reference Lab – If add-on can never be done, report the test to the Administrative Analyst

Advance Beneficiary Notice Requirements

No ABN Required

CPT Code Information

CPT Code

CPT Description

CPT Disclaimer

83885 Nickel, Quantitative  

Performing Laboratory Location

Laboratory Corporation of America (LabCorp)

LOINC Code Information

5702-6