Test Code M21 / 451927-LC MaterniT21 PLUS Core
Additional Codes
Software | Test Code |
---|---|
SoftID | M21 |
EPIC | LAB20406 |
Integrated Genetics | 451927 |
Performing Laboratory
Integrated Genetics (LabCorp Specialty Testing Group)
Useful For
For pregnancies at increased risk of fetal abnormalities, the MaterniT21 PLUS test delivers a comprehensive NIPT for the analysis of chromosomal regions including trisomies 21, 18, and 13, fetal sex.
Method Name
Cell-free DNA is isolated from the sample and analyzed using massively parallel sequencing technology.
Specimen Type
Whole Blood
Preferred Container
Strek Black and Tan Top Tube – Only the Sequenom collection KIT can be used for collection.
Preferred Volume
Whole Blood: 10 mL (Strek Black and Tan Top Tube)
Minimum Volume
Whole Blood: 8 mL (Strek Black and Tan Top Tube)
Specimen Collection and Handling
This test requires a collection kit. View additional information for collection here.
Room Temperature ONLY. Do NOT refrigerate or freeze. Keep out of direct sunlight.
Specimen Stability: 7 days
Add On Capable
Not Permitted
CPT Code Information
CPT Code |
CPT Description |
CPT Disclaimer |
---|---|---|
81420 | Fetal chrmoml aneuploidy
Fetal chrmoml aneuploidy |
Rejection Information
Gestational age less than nine weeks, expired or incorrect blood tubes (including nonglass tubes), quantity not sufficient for analysis, received more than seven days from collection, excessive hemolysis, frozen specimens.