Sign in →

Test Code K POTASSIUM, SERUM

Additional Codes

Software Test Code
Label Text K
EPIC LAB114

Performing Laboratory

NorDx Laboratories

Useful For

Evaluation of electrolyte balance and acid-base balance

Method Name

Ion-Selective Electrode (ISE)

Reference Values

3.5 - 5.1 mEq/L

Days and Times Test Performed

Monday through Sunday

Report Available

1 Day

Available Stat

Specimen Type

Submit one of the following:

~ Plasma

~ Serum

Preferred Container

Plasma Separator Tube (PST)

Serum Separator Tube (SST)

Preferred Volume

Plasma: 1 mL (Plasma Separator Tube (PST))

Serum: 1 mL (Serum Separator Tube (SST))

Minimum Volume

Plasma: 0.3 mL (Plasma Separator Tube (PST))

Serum: 0.3 mL (Serum Separator Tube (SST))

Specimen Collection and Handling

Spin specimen, separate from clot and send refrigerated within 2 hours of collection.

Specimen Stability Information

Specimen Type: Plasma

Refrigerated: 3 Days

Must be spun/separated within: 2 Hours

 

Specimen Type: Serum

Refrigerated: 3 Days

Must be spun/separated within: 2 Hours

Add On Capable

Yes

Advance Beneficiary Notice Requirements

No ABN Required

CPT Code Information

CPT Code

CPT Description

CPT Disclaimer

84132 Potassium, Serum, Plasma or Whole Blood, Quantitative  

Keywords

K

POTASSIUM

Performing Laboratory Location

NorDx Laboratories

LOINC Code Information

2823-3

Acceptable Alternative Container(s)

Dark Green Top Tube (Lithium Heparin) (Maine Medical Center - Portland Only)

Red Top Tube

Orange Top Tube (Rapid clot serum)