Sign in →

Test Code HCVVR HEPATITIS C VIRUS (HCV) RNA VIRAL LOAD WITH REFLEX TO GENOTYPE

Additional Codes

Software Test Code
Label Text                                                HCVVR                                                                   
EPIC LAB20217

Performing Laboratory

NorDx Laboratories

Useful For

Quantifying Hepatitis C RNA by PCR with Reflex to Genotype when viral load is greater than 2,000 IU/mL

Method Name

TMA (Transcription Mediated Amplification)

Reference Values

Undetected

 

Result range of the assay is 10 to 100,000,000 IU/mL. Will reflex to HCV Genotype if viral load is greater than 1,000 IU/mL.

Days and Times Test Performed

Monday or Thursday

Varies

Report Available

1 Day

Specimen Type

 Serum

Preferred Container

Serum Separator Tube (SST)

Preferred Volume

Serum: 2 mL (Serum Separator Tube (SST))

Plasma: 2 mL (Lavender Top Tube (EDTA))

Minimum Volume

Serum: 1.4 mL (Serum Separator Tube (SST))

Plasma: 1.4 mL (Lavender Top Tube (EDTA))

Specimen Collection and Handling

1. Draw blood in a serum gel tube (SST).

2. Spin down and remove serum or plasma from cells within 2 hours (24 hours for EDTA plasma).

3. Send serum or EDTA plasma frozen in a screw-capped plastic vial.

Specimen Stability Information

Specimen Type: Serum

Frozen: 6 Weeks

Refrigerated: 3 Days

Must be spun/separated within: 2 Hours

Add On Capable

Not Permitted

Advance Beneficiary Notice Requirements

No ABN Required

CPT Code Information

CPT Code

CPT Description

CPT Disclaimer

87522 Infectious Agent Detection by Nucleic Acid (DNA or RNA), Hepatitis C Virus, Quantification, Includes Reverse Transcription when Performed  
87902 Infectious Agent Drug Susceptibility Phenotype Prediction Using Regularly Updated Genotypic Bioinformatics, Hepatitis B Virus if Indicated

Performing Laboratory Location

NorDx Laboratories

LOINC Code Information

11011-4

Acceptable Alternative Container(s)

Red Top Tube

Lavender Top Tube (EDTA) plasma