Test Code COREM HEPATITIS B CORE ANTIBODY, IgM, SERUM
Additional Codes
| Software | Test Code |
|---|---|
| Label Text | COREM |
| EPIC | LAB549 |
Performing Laboratory
NorDx Laboratories
Useful For
Diagnosing acute hepatitis B infection and aiding in the diagnosis between acute or chronic hepatitis B virus infection when used with other serological markers
Method Name
Electrochemiluminescence immunoassay (ECLIA) - µ capture test principle
Reference Values
Non-Reactive (reported as Non-Reactive and Reactive)
Interpretation depends on clinical setting.
Days and Times Test Performed
Monday through Friday
Report Available
1 Day
Specimen Type
Serum
Preferred Container
Serum Separator Tube (SST)
Preferred Volume
Serum: 1 mL (Serum Separator Tube (SST))
Minimum Volume
Serum: 0.5 mL (Serum Separator Tube (SST))
Specimen Collection and Handling
Spin specimen, separate from clot and send refrigerated.
Specimen Stability Information
Specimen Type: Serum
Frozen: 3 Months
Refrigerated: 7 Days
Ambient: 7 Days
Must be spun/separated within: 2 Hours
Acceptable Alternative Container(s)
Red Top Tube
Add On Capable
Yes
CPT Code Information
|
CPT Code |
CPT Description |
CPT Disclaimer |
|---|---|---|
| 86705 | Hepatitis B Core Antibody (HBcAb), IgM |
Performing Laboratory Location
NorDx Laboratories
LOINC Code Information
31204-1
Advance Beneficiary Notice Requirements
No ABN Required