Test Code CMVAP CYTOMEGALOVIRUS (CMV) ANTIBODIES, IGG AND IGM (SEPARATE DETERMINATIONS), SEMI-QUANTITATIVE, SERUM
Additional Codes
Software | Test Code |
---|---|
Label Text | CMVAP |
EPIC | LAB10216 |
Performing Laboratory
NorDx Laboratories
Useful For
Diagnosing primary, acute phase infection with CMV especially in patients with infectious mononucleosis and pregnant women who (based on clinical signs or exposure) may have primary CMV infection. Additionally, can aid in determining whether a patient had CMV infection in the past.
Method Name
Chemilumiscent Immunoassay (CLIA)
Reference Values
CYTOMEGALOVIRUS ANTIBODIES, IGG:
Negative (Equivocal Results should be retested in 2 weeks if clinically indicated)
CYTOMEGALOVIRUS ANTIBODIES, IGM:
Negative (Equivocal Results should be retested in 2 weeks if clinically indicated)
Days and Times Test Performed
Tuesdays and Thursdays
Report Available
Up to 1 Week
Profile Information
Individual Test Description |
---|
CYTOMEGALOVIRUS (CMV) ANTIBODIES, IGG, SERUM |
CYTOMEGALOVIRUS (CMV) ANTIBODIES, IGM, SERUM |
Specimen Type
Serum
Preferred Container
Serum Separator Tube (SST)
Preferred Volume
Serum: 1 mL (Serum Separator Tube (SST))
Minimum Volume
Serum: 0.5 mL (Serum Separator Tube (SST))
Specimen Collection and Handling
Spin specimen, separate from clot and send refrigerated in a screw-capped, plastic vial.
If specimen will not arrive within 2 days of collection, send specimen FROZEN in plastic vial on dry ice.
Specimen Stability Information
Specimen Type: Serum
Frozen: 3 Months
Refrigerated: 48 Hours
Must be spun/separated within: 2 Hours
Add On Capable
Not Permitted
Advance Beneficiary Notice Requirements
No ABN Required
CPT Code Information
CPT Code |
CPT Description |
CPT Disclaimer |
---|---|---|
86644 | Cytomegalovirus (CMV) Antibodies |
Performing Laboratory Location
NorDx Laboratories
Acceptable Alternative Container(s)
Red Top Tube