Test Code CHRU / 071530-LC CHROMIUM, RANDOM URINE
Additional Codes
Software | Test Code |
---|---|
SoftID | CHRU |
EPIC | LAB10212 |
LabCorp | 071530 |
Performing Laboratory
Laboratory Corporation of America (LabCorp)
Useful For
Monitoring industrial exposure to chromium
Method Name
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)
Reference Values
Occupational exposure:
BEI® (sampling during shift): 10.0 µg /g creatinine
BEI® (sampling at end of shift): 25.0 µg /g creatinine
Days and Times Test Performed
Monday through Friday
Report Available
1 Day
Specimen Type
Urine, Random
Preferred Container
Urine Cup – No preservative
Preferred Volume
Urine, Random: 5 mL (Urine Cup)
Minimum Volume
Urine, Random: 0.6 mL (Urine Cup)
Specimen Collection and Handling
1. Sampling time is the end of the work week for industrial exposure monitoring.
2. Avoid contact with metal during collection.
3. Send specimen at ambient temperature.
Click here to view the Urine Aliquoting Guide for Processing
Specimen Stability Information
Specimen Type: Urine, Random
Frozen: 14 Days
Refrigerated: 14 Days
Room Temp: 14 Days
Note: Stable x3 freeze/thaw cycles.
Add On Capable
Contact Reference Lab – If add-on can never be done, report the test to the Administrative Analyst
Advance Beneficiary Notice Requirements
No ABN Required
CPT Code Information
CPT Code |
CPT Description |
CPT Disclaimer |
---|---|---|
82495 | Chromium, Quantitative | |
82570 | Creatinine, Other Source, Quantitative |
Performing Laboratory Location
Laboratory Corporation of America (LabCorp)
LOINC Code Information
5623-4