Test Code C-PEP C-PEPTIDE
Additional Codes
Software | Test Code |
---|---|
Label Text | C-PEP |
EPIC | LAB20344 |
Performing Laboratory
NorDx Laboratories
Useful For
Diagnosing hypoglycemia:
-Diagnosis of factitious hypoglycemia due to surreptitious administration of insulin
-Evaluation of possible insulinoma
-Surrogate measure for the absence or presence of physiological suppressibility of endogenous insulin secretion during diagnostic insulin-induced hypoglycemia (C-peptide suppression test)
Assessing insulin secretory reserve in selected diabetic patients (as listed below) who either have insulin autoantibodies or who are receiving insulin therapy:
-Assessing residual endogenous insulin secretory reserve
-Monitoring pancreatic and islet cell transplant function
-Monitoring immunomodulatory therapy aimed at slowing progression of preclinical, or very early stage type 1 diabetes mellitus
Method Name
Electrochemiluminescent Immunoassay (ECLIA)
Reference Values
1.1 – 4.4 ng/mL
Days and Times Test Performed
Monday through Sunday
Report Available
1 Day
Specimen Type
Serum
Preferred Container
Serum Separator Tube (SST)
Preferred Volume
Serum: 1 mL (Serum Separator Tube (SST))
Minimum Volume
Serum: 0.5 mL (Serum Separator Tube (SST))
Specimen Collection and Handling
1. Spin specimen, separate from clot and send refrigerated.
2. If specimen will not arrive within 1 day of draw, send specimen FROZEN.
3. Sample should not be collected on patients receiving therapy with high biotin doses (i.e. >5 mg/day) until at least 8 hours after the last biotin administration.
Specimen Stability Information
Specimen Type: Serum
Frozen: 30 Days
Refrigerated: 24 Hours
Room Temp: 4 Hours
Must be spun/separated within: 2 Hours
Add On Capable
Yes
Advance Beneficiary Notice Requirements
No ABN Required
CPT Code Information
CPT Code |
CPT Description |
CPT Disclaimer |
---|---|---|
84681 | C-peptide, S |
Keywords
C-Peptide
Insulin Connecting Peptide
c-pep
LOINC Code Information
1986-9
Acceptable Alternative Container(s)
Red Top Tube