Sign in →

Test Code AST ASPARTATE AMINOTRANSFERASE (AST), SERUM

Additional Codes

Software Test Code
Label Text AST
EPIC LAB131

Performing Laboratory

NorDx Laboratories

Useful For

Diagnosing and monitoring liver disease, particularly diseases resulting in a destruction of hepatocytes

Method Name

Enzymatic Activity

Reference Values

Males
<1 year: No reference range established
1 - <14 years: 8 - 60 U/L
≥ 14 years: 8 - 48 U/L

Females
< 1 year: No reference range established
1 - < 14 years: 8 - 50 U/L
≥ 14 years: 8 - 43 U/L

Days and Times Test Performed

Monday through Sunday

Report Available

1 Day

Available Stat

Specimen Type

Submit one of the following:

~ Plasma

~ Serum

Preferred Container

Plasma Separator Tube (PST) 

Serum Separator Tube (SST)

Preferred Volume

Plasma: 1 mL (Plasma Separator Tube (PST)) 

Serum: 1 mL (Serum Separator Tube (SST))

Minimum Volume

Plasma: 0.3 mL (Plasma Separator Tube (PST))

Serum: 0.3 mL (Serum Separator Tube (SST))

Specimen Collection and Handling

Spin specimen, separate from clot and send refrigerated.

Specimen Stability Information

Specimen Type: Plasma

Refrigerated: 7 Days

Must be spun/separated within: 2 Hours

Specimen Type: Serum

Refrigerated: 7 Days

Must be spun/separated within: 2 Hours

Add On Capable

Yes

Advance Beneficiary Notice Requirements

No ABN Required

CPT Code Information

CPT Code

CPT Description

CPT Disclaimer

84450 Transferase, Aspartate Amino (AST) (SGOT), Quantitative  

Keywords

ASPARTATE AMINOTRANSFERASE (AST)

AST (ASPARTATE AMINOTRANSFERASE)

SGOT (SERUM GLUTAMIC-OXALOACETIC TRANSAMINASE)

Performing Laboratory Location

NorDx Laboratories

LOINC Code Information

1920-8

Acceptable Alternative Container(s)

Red Top Tube

Orange Top Tube (Rapid clot serum)